Road Marking Paint and Machine Manufacturer

+86-15668659958

Usage of Road Retroreflection Measuring Instrument

20 5 月, 2024

The brightness of reflective markings is expressed internationally as the coefficient of retroreflection, in units of mcd/lx/m2. Its physical meaning is the brightness value generated per unit area under unit lighting conditions. Place the instrument above the measured line, which displays the value of the reflection coefficient in digital form, reflecting the objective evaluation of the driver’s reflection brightness of the line under driving conditions.

Features:

  1. 1.Able to measure 24/7 regardless of day, night, field, or indoor conditions;
  2. 2.The instrument is easy to operate and displays the value of the reflection coefficient in intuitive numbers;
  3. 3.The instrument is equipped with a set of standard boards and calibrated using data transmission, with high accuracy;
  4. 4.The geometric conditions for measurement are an observation angle of 1.05 ° and an incidence angle of 88.76 °, which comply with the national standard “Quality Requirements and Testing Methods for Road Traffic Standards”;
  5. 5.The instrument has a small volume, light weight, and is easy to carry

Technical indicators:
Measurement range: 0-1999 (unit: cd/lx/㎡)
Uncertainty:<5%
Observation angle: 1.05 °
Incident angle: 88.76 °
Light source color temperature: A Light source color temperature 2856K
Receiver: V; correction
Applicable ambient temperature: -20 °~50 °
Continuous working time of 10 hours for a single charge
Relative humidity 80%
External dimensions 780 x 420 x 180 (unit: mm)
Weight 18Kg

Method of use for the retroreflective coefficient tester for reflective markings

Configuration:
One measuring host; One charger; A set of standard boards; One calibration certificate; One verification certificate; One user manual
1、 Operation steps

  1. Turn on the instrument power switch (at the instrument panel). At this point, the header number is “000.” indicating that the internal power supply of the instrument has been connected. If the indication is not “000.”, please use the zero adjustment knob to adjust it to “000.”.
  2. Turn on the instrument light door switch (in the middle position of the instrument, pull out the knob about 30mm away from the chassis, do not pull it hard) and calibrate it at the same time: This instrument comes with a standard calibration board, on which calibration data is indicated. Place the measuring port at the bottom of the instrument on top of the standard board (the standard board has directionality, and the arrow points towards the driving direction), and press the measurement knob (the red button on the instrument panel). At this point, the instrument will display data. If it is not the given accuracy value, please adjust the calibration knob until the header data shows the calibration value.
  3. If there is a change in the calibration zero point, calibrate again until it displays correctly.
    After the calibration and zero adjustment operation is completed, lock the knob. At this point, measurements can be taken.
  4. When measuring, the instrument should be placed on the markings and aligned with the direction of the vehicle. According to the requirements of the reflective marking measurement technology, five points must be selected. Record the measurement results of each point, and finally take the arithmetic mean, which is the reflection coefficient of the marking.Method of use for the retroreflective coefficient tester for reflective markings

2、 Notes:

  1. Because the light source of the instrument undergoes slight changes under the action of current, in order to measure data accurately. Preheat the instrument for 10 minutes after startup.
  2. The instrument has three indicator lights to monitor the power supply of the instrument. A green light indicates that the power supply is working properly, while a red light indicates that the power supply voltage is low, and the instrument needs to be charged. When charging, if the yellow light is on. Indicates that the electricity is sufficient. Can be measured.
  3. This instrument comes with a charger. When charging, there is a charging switch on the side of the instrument. Turn on the switch and the indicator light will light up, indicating that it has been connected to the internal power supply. At this point, connect the charger to charge. The charging time is generally 3-4 hours.
  4. After each measurement, be sure to reset the light gate button and put the instrument into the instrument box for storage. Shockproof, water discharge, and dust discharge. Pay attention to the cleanliness of the standard board and do not damage it.
    When the instrument is not in use for a long time, it is necessary to charge and maintain the instrument battery to prevent the battery activity from weakening.
    When the instrument light door switch is not open, if the measurement button is pressed, data will also appear. This data is the monitoring data of the instrument light source and is not related to actual measurement. Please be aware.
  5. If the instrument malfunctions, please contact the supplier in a timely manner and do not disassemble or repair it yourself to avoid unnecessary damage

Method of use for the retroreflective coefficient tester for reflective markings,

Our company is a professional manufacturer of road hot-melt coatings, road retroreflective measuring instruments, and road marking machines. If you are interested, please feel free to communicate with me via email at any time export@toproadtraffic.com

测量仪